• English
  • Polski
  • Deutsch
  • PIANO SYSTEM RECTANGULAR COWL ND+I

     

    Piano System Cowl ND+I -Primarily designed for building roofs to protect various types of
    installations: ventilation, air conditioning, plumbing, electrical from
    atmospheric conditions. They come in both “without” and “with” pre-made
    technical openings, rectangular and/or circular, in any quantity, which
    can be used for the installation of roof intakes and outlets, sanitary
    outlets, or electrical cable conduits in buildings, including
    residential, collective housing, and public utility buildings. They can
    also be used in warehouses, industrial buildings, and utility buildings.

    The Piano System Cowl ND+I with a rectangular cross-section consists
    of a ventilation straight duct bent at a 90-degree angle and a cover
    with a shield. The inner duct shell and the outer duct shell are
    connected by welding at the point of contact. The duct and cover are
    made of galvanized steel sheet DX51D with a zinc coating Z275 according
    to the PN-EN 10346:2015 standard. Between them, there is polyurethane
    foam (PUR) insulation with a thickness of 25 ÷ 100 mm. The dimensions of
    the outer duct shell depend on the thickness of the applied foam
    insulation layer. The minimum thickness of the inner and outer duct
    shell sheet metal is 0.5 mm.
    Connections (collar frames) used in the inner duct shell and the outer
    duct shell are made of P-20 or P-30 profiles and N-20 or N-30 corners,
    made of galvanized steel sheet DX51D+Z275 according to the PN-EN
    10346:2015 standard.

     

    1. INNER JACKET
    2. OUTER JACKET
    3. POLYURETHANE FOAM LAYER4. THE COWL FLANGE IS FIXED TO THE CEILING WITH E.G. ANCHORS
    5. WATERPROOFING MEMBRANE – FLOOR LAYER
    6. FLOOR
    7. INNER JACKET FRAME
    8. OUTER JACKET FRAME
    9. INTAKE VENT
    10. TYPE C ROOF OUTLET WITH ADDITIONAL FLANGE

     

     

     

     

     

     

     

     

     

     

    Depending on the type of installation that Piano System Cowl ND+I are intended to protect, they come in several variants that can be freely combined or modified as needed:

    VARIANT I – SCREW-ON CAP for ducts with screws and self-locking nuts

    VARIANT II – HINGED CAP – Hinged flap

    Option 1 – CAP WITHOUT OPENINGS

     

    Option 2 – CAP WITH OPENINGS – quantity, shape, and dimensions of openings according to the Customer’s specification

    Side A – SIDES WITHOUT OPENINGS Piano System Cowl ND+I without technical openings

     

     

     

     

    Side B – SIDES WITH OPENINGS Piano System Cowl ND+I with a rectangular or circular technical opening, ready for installation, e.g., wall intakes/outlets. The number of openings is arbitrary on each side of the cap.

     

    Types:

    1. [I-1-A] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 1 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    2. [I-1-B] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 1 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    3. [I-2-A] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 2 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    4. [I-2-B] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 2 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    5. [II-1-A] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 1 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    6. [II-1-B] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 1 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    7. [II-2-A] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 2 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    8. [II-2-B] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 2 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)

    The inner duct shell and the outer duct shell of the straight duct are joined longitudinally using sheet metal locks (Pittsburgh type lock) or welded. The corners of the collar frames are sealed with silicone sealant.

    Assembly variants of the Piano System Cowl ND+I cover:

    1. Cover connected on one side with steel hinges, mounted using rivets, creating a hinged flap, which can additionally be secured with M8 screws (for N+P20 collar) or M10 screws (for N+P30 collar) and self-locking nuts.
    2. Assembly of the cover using collar connections, fastened with M8 screws (for N+P20 collar) or M10 screws (for N+P30 collar) according to DIN 933 or PN-EN ISO 4017:2014 and self-locking nuts. The Nasada ND+I is installed on the ceiling using expansion plugs, one in each corner and on the sides at a distance of every 0.5 m. Collar connection frames of the cover with the duct of the Piano System Cowl ND+I (for the outer duct shell) elements with a side length greater than 500 mm can (but do not have to) be additionally reinforced with sheet metal clamps. The maximum distance between the clamps at the corner collar connection and relative to each other should be 500 mm.

     

    ZATRUDNIMY BLACHARZY WARSZTATOWYCH - Przyjdź i sprawdź ile możesz zyskać!